← All decks

Anaesthesiology

Commonly Used Monitoring Techniques

Built from Barash Clinical Anesthesia, 9th Edition

What’s inside

15 sections · 193 slides

  1. 01

    Overview

    • Purpose of anaesthesia monitoring
    • Scope of this topic
    • Framework used for each monitor
    • Evidence and cost of monitoring

    4 slides

  2. 02

    Standards for Basic Anesthetic Monitoring

    • ASA basic monitoring standards
    • Standard I: qualified personnel
    • Standard II: the four variables evaluated
    • Oxygenation requirements under Standard II
    • Ventilation requirements under Standard II
    • Circulation and temperature requirements

    6 slides

  3. 03

    Monitoring of Inspired Oxygen Concentration

    • Three types of oxygen analyser
    • Paramagnetic oxygen analysers
    • Galvanic cell oxygen analysers
    • Polarographic oxygen analysers
    • Placement of the oxygen sensor in the circuit
    • Performance requirements and calibration
    • Alarm limits at machine checkout
    • Indications for inspired oxygen monitoring
    • Limitations of inspired oxygen monitoring

    9 slides

  4. 04

    Monitoring of Arterial Oxygenation by Pulse Oximetry

    • Variables measured by a pulse oximeter
    • Shape of the oxyhaemoglobin dissociation curve
    • Rightward shift of the dissociation curve
    • Application of the Beer-Lambert law
    • Extraction of the pulsatile arterial signal
    • Functional saturation measured by pulse oximetry
    • Fractional saturation measured by a co-oximeter
    • Functional versus fractional saturation
    • Effect of methaemoglobin on the reading
    • Effect of carboxyhaemoglobin on the reading
    • Factors that corrupt the oximeter signal
    • Interference from theatre equipment
    • Indications and reported accuracy
    • Questions pulse oximetry cannot answer
    • Desaturation as a late sign of apnoea
    • Pulse oximetry with non-pulsatile circulation
    • Pulse oximetry in infants and children

    17 slides

  5. 05

    Monitoring of Expired Gases

    • Historical gas-analysis techniques
    • Principle of infrared absorption spectrophotometry
    • Infrared transmission spectra of carbon dioxide and nitrous oxide
    • Five components of an infrared gas analyser
    • Simultaneous multi-gas measurement
    • Critical events revealed by gas analysis
    • Detection of critical events by gas analysis
    • Detection of critical events by gas analysis (continued)
    • Capnometry and capnography defined
    • Phases of the normal capnogram
    • End-tidal to arterial carbon dioxide gradient
    • Abnormal capnogram shapes
    • Capnography and endotracheal tube placement
    • Sudden loss of the carbon dioxide waveform
    • Abrupt versus gradual falls in end-tidal carbon dioxide
    • Rebreathing on the capnogram
    • Physiological determinants of end-tidal carbon dioxide
    • Factors that may change end-tidal carbon dioxide during anaesthesia
    • Factors that may change end-tidal carbon dioxide during anaesthesia (continued)
    • Monitoring inspired and expired agent concentration
    • Minimum alveolar concentration
    • End-tidal agent monitoring and awareness
    • Nitrogen monitoring and its loss
    • When end-tidal carbon dioxide misrepresents arterial carbon dioxide
    • Capnography in neonates and small infants

    25 slides

  6. 06

    Invasive Monitoring of Systemic Blood Pressure

    • Generation of the arterial pressure trace
    • Sources of error in fluid-coupled systems
    • Damping and natural frequency
    • Acceptable damping for a given natural frequency
    • Consequences of underdamping and overdamping
    • Optimising the transducing system
    • Choice of arterial cannulation site
    • Arterial cannulation and direct blood pressure monitoring
    • Arterial cannulation and direct blood pressure monitoring (continued)
    • Value of the Allen test
    • Techniques for arterial cannulation
    • Zeroing and levelling the transducer
    • Transducer level in the beach-chair position
    • Vascular complications of arterial cannulation
    • Indications for an arterial catheter
    • Contraindications to arterial cannulation
    • Safe handling of arterial line blood and tubing

    17 slides

  7. 07

    Intermittent Noninvasive Monitoring of Systemic Blood Pressure

    • Korotkoff sounds
    • The oscillometric method
    • Sequence of oscillometric pressure determination
    • Contraindications to cuff placement
    • Cuff injury during prolonged surgery
    • Cuff size and limb position errors
    • Non-pulsatile flow and cuff measurement
    • Alternative cuff sites and site-dependent readings

    8 slides

  8. 08

    Monitoring of Central Venous and Right-Heart Pressures

    • Uses of a central venous cannula
    • Central venous pressure as right ventricular preload
    • Unreliability of right-sided pressures for left ventricular filling
    • Advantages of the pulmonary artery catheter
    • Progression of pressures from central vein to left ventricle
    • Components of the normal central venous pressure trace
    • Abnormal a waves
    • Abnormal v waves
    • Central venous versus pulmonary artery monitoring
    • Pressure waveforms during catheter flotation
    • West zones of the lung
    • Verifying that the catheter tip lies in zone III
    • Indications for a pulmonary artery catheter
    • Conditions that invalidate the wedge pressure
    • Dysrhythmias during catheter passage
    • Pulmonary artery rupture
    • Reported incidence of catheter complications
    • Adverse effects associated with pulmonary artery monitoring
    • Adverse effects associated with pulmonary artery monitoring (continued)
    • Choice of central venous access site

    20 slides

  9. 09

    Monitoring of Cardiac Output by Pulmonary Arterial Catheter

    • Indicator dilution principle
    • Bolus thermodilution cardiac output
    • Continuous cardiac output monitoring
    • Error from a catheter not advanced far enough
    • Other sources of thermodilution error
    • Indications for measuring cardiac output
    • Assumptions behind thermodilution

    7 slides

  10. 10

    Monitoring of Cardiac Output by Arterial Waveform Analysis

    • Motivation for less invasive cardiac output
    • Non-invasive finger cuff cardiac output
    • The volume-clamp principle
    • The Windkessel model of the artery
    • Blood flow into and out of a Windkessel artery
    • Areas under the systolic and diastolic pressure curve
    • Proportionality of systolic and diastolic flows to their areas
    • Stroke volume from the pressure-curve areas
    • The calibration constant k
    • Indices reported by uncalibrated devices
    • Indications for arterial waveform cardiac output
    • Signal quality requirements
    • High-output states and vascular tone
    • Aortic valve lesions and waveform analysis

    14 slides

  11. 11

    Monitoring of Body Temperature

    • Thermoregulation under anaesthesia
    • Four routes of heat loss
    • Physiological consequences of perioperative hypothermia
    • Sites for measuring core temperature
    • Mean body temperature
    • Limitations of skin and rectal temperature

    6 slides

  12. 12

    Monitoring of Processed EEG Signals

    • Electroencephalography for cerebral ischaemia
    • Applying the forehead sensor
    • Beta-power ratio
    • Power concentration in the gamma band
    • Burst suppression ratio
    • Open algorithm for processing the EEG into a depth score
    • Interpreting the displayed number
    • Agent dependence of the processed EEG score
    • Indications for processed EEG monitoring
    • Contraindications to processed EEG sensors
    • Evidence on processed EEG and intraoperative awareness
    • Awareness and anaesthetic exposure in children

    12 slides

  13. 13

    Monitoring Neuromuscular Blockade

    • Rationale for monitoring neuromuscular blockade
    • The two steps of neuromuscular monitoring
    • Quantitative neuromuscular monitors
    • Three categories of neuromuscular monitor
    • Mechanomyography and acceleromyography
    • Technique at the ulnar nerve
    • Consensus recommendation on neuromuscular monitoring
    • Underuse of neuromuscular monitoring
    • Hazard of facial stimulation sites
    • Practical limitations of acceleromyography
    • Practical limitations of electromyography

    11 slides

  14. 14

    Future Trends in Monitoring

    • Three trends in monitoring device design
    • Anaesthesia information management systems
    • Algorithmic inference of clinical data
    • Obligation of clinical judgement

    4 slides

  15. 15

    Key Points

    • Key points on oxygen and gas monitoring
    • Key points on pressure and flow monitoring
    • Key points on temperature, brain and judgement
    • The unchanging principle of monitoring
    • References
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • Barash, Cullen, and Stoelting's Clinical Anesthesia, 9th Edition

    19 slides